TR-165 Cu/Cu double shielded Coaxial Cable Class A for Burying with LSFH sheath and Euroclass Dca
What are the main characteristics of the Televes 214911 Coaxial Cable?
- Conductors made of copper
- Class A shielding
- Euroclass Dca-s2, d2, a1
- Petro-gel layer
- LSFH outer cover, UV resistant, gray
- Characteristic impedance of 75 ohm
- 250m wooden spool
What technical specifications does the Televes 214911 Coaxial Cable have?
Tipo | TR-165 | |||
Estándard | EN 50117-2-5 | |||
EuroClase | Dca-s2,d2,a1 | |||
Clase | A | |||
Conductor central | Ø mm | 1,63 | ||
Material | CU | |||
Res. Ohm/Km | 9 | |||
Dieléctrico | Ø mm | 7,2 | ||
Material | PEE | |||
Lámina interior | Aluminio + Polipoprileno + Aluminio | |||
Malla | Material | Cu | ||
Dimensiones (Ncx Nsx Ø) | 16 x 8,5 x 0,148 | |||
Res. Ohm/Km | <7 | |||
% cobertura | 77 | |||
Lámina antimigratoria | No | |||
Petro-Gel | Sí | |||
Cobertura exterior | Ø mm | 10,1 | ||
Material | LSFH, Resistente UV | |||
Radio de curvatura mínimo | mm | 50 | ||
Blindaje a 1GHz | dB | >85 | ||
Capacidad | pF/m | 53 | ||
Impedancia | Ohm | 75 | ||
Impedancia de Transferencia (5-30MHz) | mOhm/m | ≤5 | ||
Velocidad de propagación mín. | % | 84 | ||
Atenuaciones (dB/m) | ||||
Frecuencia (MHz) | ||||
5 | 0,005 | |||
47 | 0,02 | |||
90 | 0,04 | |||
200 | 0,05 | |||
500 | 0,09 | |||
800 | 0,11 | |||
1000 | 0,13 | |||
1350 | 0,15 | |||
1750 | 0,18 | |||
2050 | 0,19 | |||
2300 | 0,21 |