Transmodulator with remultiplexing by Televes DVBT / S / S2 COFDM.
What are the main features of the Televes 564301 transmodulator?
- It allows the installer, in addition to configuring the services to the exit, to eliminate a concrete PID of some of the services.
- Configurable and remotely monitorable through CDC.
- They provide useful rate information for each of the input services, showing the occupation of the output channel.
- TWIN output signal fully configurable (2 muxes).
- DiSEqC.
- Configurable CAM position.
- LCN and combined SID issue on both muxes that prevents TV retune when updating the channel grid.
What are the technical specifications of Televes 564301 transmodulator?
References | 564201 | 564301 | |||
SAT INPUT | SAT | Input frequency range | MHz | 950...2150 | |
Frequency steps | 1 | ||||
Input level | dBμV | 42 - 82 | |||
Loop-through losses | dB | ≤ 1,5 | |||
LNB powering | Vdc | 13V/17V/ OFF - 22KHz (ON/OFF) | |||
Input return losses (typ.) | dB | > 10 | |||
Input impedance | Ω | 75 | |||
DVB-S | Symbol rate (Modulation) | Mbaud | 2 - 42,5 (QPSK) | ||
FEC inner code | Viterbi (1/2, 2/3, 3/4, 5/6, 7/8) | ||||
FEC outer code | RS (188/204) | ||||
Roll-Off factor | % | 35 | |||
DVB-S2 | Symbol rate (Modulation) | Mbaud | 10 - 30 (QPSK, 8PSK) | ||
FEC inner code | LDPC (1/2, 1/3, 1/4, 2/3, 2/5, 3/4, 3/5, 4/5, 5/6, 8/9, 9/10) | ||||
FEC outer code | BCH (Bose-Chaudhuri-Hocquenghem) | ||||
Roll-Off factor | % | 20, 25, 35 | |||
DTT OUTPUT | COFDM | Modulation (Constellation) | QPSK, 16QAM, 64QAM | ||
Guard interval | μs | 1/4, 1/8, 1/16, 1/32 | |||
Scrambling | DVB EN 300744 | ||||
Interleaving | DVB EN 300744 | ||||
Convolutional code (FEC) | Viterbi (1/2, 2/3, 3/4, 5/6, 7/8) | ||||
PCR Correction | Sí | ||||
Services deleting | Sí | ||||
Network_ID | Sí | ||||
Original Network_ID | Sí | ||||
Cell_ID | Sí | ||||
TS_ID | Sí | ||||
S_ID | Sí | ||||
LCN | Sí | ||||
Spectral inversion | Normal, Inverted | ||||
Channel bandwidth | Mhz | 7,8 | |||
RF | Output frequency | 45 - 862 | |||
Frequency steps | KHz | 166 - 125 (user selectable) | |||
Output level (max. typ.) | dBμV | > 80 ± 5 | |||
Output level regulation margin | dB | >15 | |||
Output loop-through losses | < 1,5 | ||||
Output return losses (typ.) | > 12 | ||||
Output impedance | Ω | 75 | |||
GENERAL | Powering voltage | Vdc | 24 | ||
Consumption | mA | 520 (0 CAM - 0 LNB) 620 (1 CAM - 0 LNB) 870 (0 CAM - 1 LNB) 1120 (1 CAM - 2 LNBs) |
530 (0 CAM - 0 LNB) 630 (1 CAM - 0 LNB) 880 (0 CAM - 1 LNB) 1130 (1 CAM - 2 LNBs) |
||
Protection index | IP | 20 |