Loading...

Field Meter H30Crystal DVB-S/S2 +DVB-T+F.O. Selective(Cat F)

SKU
TEL593621
Brands: Televes
Availability: On request
1 to 7 days
Free shipping
(Iberian Peninsula)
€2,857.35 Tax included
-
+

Field Meter H30Crystal DVB-S/S2 +DVB-T+F.O. Selective (Cat F)

This Crystal Series Field Meter is ideal for today's installer. Specially designed for category F of the ICT, dedicated to new generation telecommunications installations.

The meter is light and compact, very versatile. It incorporates the ability to perform optical measurements, so it is possible to analyze fiber optic networks, in addition to the common functionalities.

The device measures DVB-S/S2, DVB-T/T2, DVB-C, analog and return channels. Multiscreen system, since you can use it through its 2.8” TFT screen or you can connect it to an external screen, smartphone or tablet, to control the equipment remotely (for this function you must install the H30Suite app).

What makes this meter different is that the equipment integrates an optical receiver that allows accurate measurement of power and attenuation at 1310nm, 1490nm and 1550nm wavelengths (the receiver has a selective or non-selective option).

The meter has an ideal size with a very light weight, connectivity through Wifi and Bluetooth, intuitive and simple menu. Measurements are made with the push of a button.

Technical Specifications of the Field Meter H30Crystal DVB-S/S2 +DVB-T+F.O. Selective (Cat F)

H30Crystal
Mechanical Specifications
Screen 2.8” TFT 400 x 240 full color
Weight 550 g.
Dimensions 175x100x52 mm / 6,9x3,9x2 (HxWxD)
AC Adaptor Input: 100-240V~ 50-60Hz Output: 12VDC, 2A
Battery Li-ion (7,2VDC, 2300mAh)
Baterry range >4hours without LNB powering
Interfaces Bluetooth, Wi-Fi 2.4GHz / 5 GHz, Ethernet 1Gb
USB 2.0 for Data log download and software upgrades
Resilience It withstands drops From 1 m (3.2 ft) onto concrete on all sides
Storage capacity 400 MB (internal) for measurements
Impedance F-type connector - 75 Ohm

 

Technical Specifications
    593603 593601 593602 593604 593621 593622 593624 593661
Frecuency
Range   Return path: 5-50 MHz / Terrestrial: 50 - 880 MHz / Satellite: 950 - 2400 MHz / Wideband: 250 - 2350 MHz
Resolution   125 kHz
Tunning   Frecuencia o canal
Spectrum analyser
Span   5, 10, 20, 50, 100, 200, 500 MHz and Full
Scale   5 and 10 dB/div
Reference level (automatic and manual)  
Optical fibre
Not Selective -40dBm to +7dBm - - -
Selective -40dBm to +7dBm - - - - -
RF Overlay -10dBm to +5dBm
Optical Attenuation  
DVB-S digital measurements [Modulation: QPSK]
Image  
Power From 45 to 110 dBμV
  From 45 to 120 dBμV Upgrade 593235** Upgrade 593235** Upgrade 593235** Upgrade 593235** Upgrade 593235** Upgrade 593235** Upgrade 593235** Upgrade 593235**
CBER 9.9E-2 – 1.0E-6
VBER 1.0E-4 – 1.0E-8
MER Up to 20dB
C/N Up to 20dB
Constelation  
DiSEqC  
SCR EN 50494
dCSS EN 50607 Upgrade 593234**
DVB-S2 digital measurements [Modulations: QPSK, 8PSK]
Image  
Power From 45 to 110 dBμV
  From 45 to 120 dBμV Upgrade 593235** Upgrade 593235** Upgrade 593235** Upgrade 593235** Upgrade 593235** Upgrade 593235** Upgrade 593235** Upgrade 593235**
Link Margin Up to 10 dB
MER Up to 20 dB
LDPCBER* 9.9E-2 – 1.0E-6
BCHBER* 9.9E-2 – 1.0E-8
Constelation  
DiSEqC  
SCR EN 50494
dCSS EN 50607 Upgrade 593234**
DVB-T digital measurements [Modulations: COFDM (QPSK, 16QAM, 64QAM)]
Image   Upgrade 593231 Upgrade 593231
Power From 45 to 110 dBμV Upgrade 593231 Upgrade 593231
  From 45 to 120 dBμV Upgrade 593231 + Upgrade 593235** Upgrade 593235** Upgrade 593235** Upgrade 593235** Upgrade 593235** Upgrade 593235** Upgrade 593235** Upgrade 593231 + Upgrade 593235**
CBER 9.9E-2 – 1.0E-6 Upgrade 593231 Upgrade 593231
VBER 1.0E-3 – 1.0E-8
MER Up to 35 dB
C/N Up to 40dB
Echoes  
Constelation  
DVB-T2 digital measurements [Modulations: COFDM ( QPSK, 16QAM, 64QAM and 256 QAM)]
Image   Upgrade 593231 + Upgrade 593232 Upgrade 593232 Upgrade 593232 Upgrade 593232
Power From 45 to 110 dBμV Upgrade 593231 + Upgrade 593232 Upgrade 593232 Upgrade 593232 Upgrade 593232
  From 45 to 120 dBμV Upgrade 593231 + Upgrade 593232 + Upgrade 593235** Upgrade 593232 + Upgrade 593235** Upgrade 593235** Upgrade 593235** Upgrade 593232 + Upgrade 593235** Upgrade 593235** Upgrade 593235** Upgrade 593232 + Upgrade 593235**
LDPCBER* 9.9E-2 – 1.0E-6 Upgrade 593231 + Upgrade 593232 Upgrade 593232 Upgrade 593232 Upgrade 593232
BCHBER* 1.0E-3 – 1.0E-8
Link Margin Up to 30 dB
MER Up to 35 dB
C/N Up to 40dB
Echoes  
Constelation  
DVB-C digital measurements [Modulations: 16QAM, 32QAM, 64QAM, 128QAM and 256 QAM]
Image   Upgrade 593233 Upgrade 593233 Upgrade 593233 Upgrade 593233 Upgrade 593233
Power From 45 to 110 dBμV Upgrade 593233 Upgrade 593233 Upgrade 593233 Upgrade 593233 Upgrade 593233
  From 45 to120 dBμV Upgrade 593235** Upgrade 593233 + Upgrade 593235** Upgrade 593233 + Upgrade 593235** Upgrade 593235** Upgrade 593233 + Upgrade 593235** Upgrade 593233 + Upgrade 593235** Upgrade 593235** Upgrade 593233 + Upgrade 593235**
CBER 1.E-2 – 1.0E-8 Upgrade 593233 Upgrade 593233 Upgrade 593233 Upgrade 593233 Upgrade 593233
MER Up to 38
C/N Up to 40dB
Digital measurements ISBT-T/Tb
Image   - - - - - - -
Power From 45 to 110 dBμV - - - - - - -
  From 25 to 120 dBμV - - - - - - - Upgrade 593235
Pre-VER (by layer) 9.9E-2 – 1.0E-6 - - - - - - -
Post-VER (by layer) 1.0E-3 – 1.0E-8 - - - - - - -
MER Up to 35 dB - - - - - - -
C/N Up to 40dB - - - - - - -
Echoes   - - - - - - -
Constelation   - - - - - - -
Analogue measurements
Level 25 and 125 dBμV
V/A  
C/N Up to 45dB
Measurements and functions
Wifi analyzer   Upgrade 593250 Upgrade 593250 Upgrade 593250 Upgrade 593250 Upgrade 593250 Upgrade 593250 Upgrade 593250 Upgrade 593250
IPTV analyser   Upgrade 593251 Upgrade 593251 Upgrade 593251 Upgrade 593251 Upgrade 593251 Upgrade 593251 Upgrade 593251 Upgrade 593251
HEVC display (up to 1080p)   Upgrade 593252 Upgrade 593252 Upgrade 593252 Upgrade 593252 Upgrade 593252 Upgrade 593252 Upgrade 593252 Upgrade 593252
Analog A/V display   Upgrade 593236 Upgrade 593236 Upgrade 593236 Upgrade 593236 Upgrade 593236 Upgrade 593236 Upgrade 593236 Upgrade 593236
Terrestrial plans   Channel plans from different regions of the world
Satellite plans   Channel plans from different regions of the world
Units   dBμV, dBmV, dBm
Powering   24 Vdc / 140 mA max.
LNB: 13, 18 Vdc / 475, 370 mA max.
LNB tono   22 kHz

* Notes:
LDPCBER is the BER measurement before LDPC correction.
BCHBER is the BER measurement after LDPC corrector and before BCH correction.

** Ref. 593234 & 593235: Free upgrade when registering the equipment

More Information
EAN 8424450237786
System Field Meters
SERIE H30
Color Gray
DVB-C Yes
DVB-S Yes
DVB-T Yes
Fibra Yes
CCTV No
Product Brand Televes
Write Your Own Review
You're reviewing:Field Meter H30Crystal DVB-S/S2 +DVB-T+F.O. Selective(Cat F)
Your Rating
File Label Size Download
pdf Ficha Técnica del Medidor de Campo H30Crystal 902.2 KB Download